EasyManua.ls Logo

Rosemount 3144 - APPENDIX D Hazardous Area Approval Installation Drawings; Overview; IMPORTANT

Rosemount 3144
119 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Rosemount Model 3144 and 3244MV Smart Temperature Transmitters
2-2
COMMISSIONING: ON THE
BENCH OR IN THE LOOP
The transmitter may be commissioned before or after installation.
However, it may be useful to commission the transmitter on the bench
before installation to ensure proper operation and to familiarize
yourself with its functionality.
Figure 2-1. Installation Flowchart.
START
HERE
Set Units
Set Range
Values
Set Sensor
Type
Set Number
of Wires
Set Damping
Set Jumpers
or Switches
Mount the
Transmitter
Wire the
Transmitter
Power the
Transmitter
Check for
Process Leaks
DONE
Simulate
Sensor Input
No
Yes
No
Yes
Bench
Calibration?
BASIC SETUP VERIFY FIELD INSTALL
Within
Specifications?
Refer to
Section 4:
Maintenance

Table of Contents

Related product manuals