B-3
Model 275 HART Communicator
Figure B-1. HARTCommunicator Menu
Tree for the Model 3144 and 3244MV.
1 DEVICE SETUP
2PV
3AO
4LRV
5URV
1 PROCESS
VARIABLE
2 DIAGNOSTICS
AND SERVICE
3BASICSETUP
4DETAILED
SETUP
5Review
PV—Engineering Units
PV—Percent Range
PV—Analog Output
SV
(TV)
(QV)
Variable Mapping
VARIABLE RE-MAP
1 TEST DEVICE
2 LOOP TEST
3 CALIBRATION
4 Smart Calibration
1Tag
2PVUnits
3PVDamp
4 Range Values
5 SENSOR 1 CONN
6 Sensor 1 Sensor s/n
7 SENSOR 2 CONN
8 Sensor 2 Sensor s/n
1 SENSORS
2 SIGNAL
CONDITION
3OUTPUT
CONDITION
4Device
Information
1PV
2PVUnits
3PVis
4SENSOR
SETUP
5SENSOR
LIMITS
6SENSORTRIM
1SENSOR1
CONFIG
2SENSOR2
CONFIG
3ConfigHot
Backup
4 DRIFT
ALERT
5MISC
CONFIG
1PROCESS
SENSOR
2 TERM TEMP
SENSOR
3 A/D CONV
INFORMATION
1 Sensor 1 Input
Trim
2 Sensor 2 Input
Trim
3Snsr1
Trim-Facto ry
4Snsr2
Trim-Facto ry
5SENSOR
CURRENT
1 Sensor 1
Limits
2 Sensor 2
Limits
1Snsr1Conn
2Snsr1Damp
3Snsr1Unit
4SpcSnsr1Con
5DisSpcSnsr1
6Snsr1Snsrs/n
1Snsr2Conn
2Snsr2Damp
3Snsr2Unit
4SpcSnsr2Con
5DisSpcSnsr2
6Snsr2Snsrs/n
1 Term Temp Unit
2DiffUnits
3DiffDamp
4 Average Units
5 Average Damp
1DriftAlertMode
2DriftUnits
3DriftLimit
4DriftDamping
5 Drift Alarm Stat.
Active Calibrator
1 Term Temp
2 Term Temp Unit
3 Term Temp
Damp
4 Term Temp
Limits
1 50/60 Hz Filter
1PVLRV
2PVURV
3PV%Range
4PVDamp
1 ANALOG
OUTPUT
2 HART OUTPUT
3 METER
OPTIONS
4 ALARM
VALUES
5 INTERMITTENT
DETECT
1 Analog Output
2AOAlarmType
3 LOOP TEST
4D/ATrim
5 Scaled D/A Trim
1 Poll Address
2 Num Req Preams
3 Burst Mode
4 Burst Option
14mA
220mA
3 Other
4End
1 Meter Type
2 Meter Decimal Pt
3 Meter Bar Graph
1HighAlarm
2LowAlarm
3 High Saturation
4 Low Saturation
1 Intermit Detect
2 Threshold Value
1PV
2SV
3TV
4QV
1 Differential Temperature
2 Terminal Temperature
3 Sensor 1
4 Sensor 2
5 Sensor Average
1 Status
2 Self Test
3 Master Test
14mA
220mA
3 Other
4End
1 Apply Values
2 RANGE VALUES
3SENSORTRIM
4D/ATrim
5 Scaled D/A Trim
1PVLRV
2PVURV
3PVEng.Units
4 PV Low Snsr Lmt
5 PV Upr Snsr Lmt
1 Snsr 1 Input Trim
2 Snsr 2 Input Trim
3 Snsr 1 Trim-Fctry
4 Snsr 2 Trim-Fctry
5 SNSR CURRENT
Active Calibrator
Select Sensor Type
Number of Wires
Any reference to Sensor 2,
Differential Temperature,
Sensor Average, Hot
Backup, Drift Alert, or TV/QV
applies to the use of a Model
275 HART Communicator to
communicate with a Model
3244MV only.
The Review menu lists all of the
informationstoredinthetransmitter.
This includes device information,
measuring element, signal condition,
output condition, and software revision.