Pumpenbetrieb vom Fahrerhaus aus
Pump Operation from Driver´s Cabin
S50 20
S46
H65
S48
S51
S315 SF2
SF3
SF4
SF1
111 112
S47
Pump Operation from Driver´s Cabin
Switching off turret discharge from turret RM 25 E
- Press switch (SF2) to close the foam compound tank suction
valve.
- Bring rpm down to idle.
- Release switch (S50).
- Press switch (S47).
This puts the turret in the park position.
** If the P.T.O. is not engaged, screen (111) will be shown,
asking the operator to engage the P.T.O. which is described under
"Engaging the Pump".
Only after the pump registers a pressure above 2 bar, does the
screen change from (111) to (112) the turret valves are then
released for operation.
ATTENTION !
After using foam compound, it is important to flush the complete
system. Refer to the "Flushing after Foam Operation" chapter.
If the turret is not equipped with an areating pipe use AFFF foam
compound, otherwise the foam quality will be poor.
For further information, please refer to the separate operation
manual of RM 25 E.