Connecting between MD-N33 and AC-215
40 AC-215 Installation Manual
To prevent access to AxTraxNG data from non-authorized users, the AC-215
contains a password that can be changed only when the modem is connected
and there is a link with AC-215.
The default password is AxTrax.
You may be asked to enter the password during first data configuration like
adding a new panel or downloading a new firmware.
B.9 Restoring Factory Default Configuration
If you forgot the existing password, there is an option to return AC-215 to
factory default (with password: AxTrax)
Returning to factory default changes also all the doors and readers
configuration to factory default and clears all the users' properties.
To restore factory default configuration:
1. Turn off the supply power.
2. It is recommended to disconnect the doors and readers wiring.
3. Connect Data 0, Data 1 and Tamper inputs to GND (-) in both Reader 1
and 2 (totally 6 wires!)
4. Power up the supply power for few seconds and wait for the control LEDs
to flash.
5. Turn off the supply power.
6. Connect the doors and readers wiring again.
7. Delete the panel by clearing the Enable panel checkbox in the panel
screen and clicking OK.
8. Check Enable panel in the panel screen and click OK. This action causes
a full setting of the AC-215 with the pervious configuration.
9. Dial the proper AC-215 ACU and click password in the
modem status
screen. You may enter the "current password" as AxTrax and change the
password to a new one.