2. Technical Specifications
2.1. ME-1515 Enclosure
ELECTRICAL SPECIFICATIONS
Enclosure SMPS
Input: 100 to 240 VAC, 1.6 A, 50–60 Hz, switch mode power management board
C13 power cord
Output: 12 VDC, 4 A
PCBA Input Power 15 VDC, 2 A, regulated power management board
Backup Battery (sold separately) 12 V sealed lead acid (SLA) up to 7 Ah, IEC62133
Relay Outputs 5 A DC, 150 W maximum
Auxiliary Outputs 12 VDC, 1.2 A typical (1.5 A max.)
Fuse 250 V, 2.5 A
OPERATIONAL SPECIFICATIONS
Relays 5 A, Form-C 6
Supervised Inputs 12
Readers (Wiegand Format)* 4
Readers (OSDP Format)* 2
Expansion Ports 1
Connectivity TCP/IP, OSDP
OPERATIONAL SPECIFICATIONS (AC-825IP Only)
Capacity Up to 100,000 users
History Event Log Size Up to 500,000 entries
Time Zones and Groups
256 multi-segment time zones,
64 holidays each holiday can be multiple days
Practically unlimited amount of access groups
Special Features with
AxTraxNG/AxTraxPro Control
Management Software
Interlock, first-person delay, auto-relock, scheduled outputs operation,
4 programmable site codes, extended unlocked time, fully interconnectedness, car
parking management, antipassback (per reader, between readers)
Security Modes Normal and Secure
*AxTraxNG supports 4 Wiegand and 2 OSDP V1 plus up to 12 expansions.
* AxTraxPro supports 4 Wiegand and 2 OSDP V2 plus up to 12 expansions or 6 OSDP V2 devices.
ENVIRONMENTAL SPECIFICATIONS
Operating Temp. Range -5°C to 50°C (23°F to 122°F)
Storage Temp. Range -25°C to 50°C (-13°F to 122°F)
Operating Humidity Range 0 to 85% (non-condensing)