5. In seven seconds or less, set all the DIP switches to OFF.
As the restore to factory defaults process continues, the red LED of the G bus flashes quickly.
6. Wait 90 seconds for the restore to factory defaults process to be fully completed.
•
When the restore to default process is complete, the red LED of the G bus flashes slowly for 5 seconds.
•
Then the panel will start the initialization process (at this time the panel is not available to operate).
•
When the initialization process is complete, the red LED of the G bus will continuously flash slowly.
6. Communications
Communication lines are used to upload and download information between the AC-825IP panel and the
AxTraxNG/AxTraxPro server using an IP network.
6.1. TCP/IP Network Connection
The computer running the AxTraxNG/AxTraxPro server can communicate with the access control panels via an IP
network. The connection settings are controlled within the AxTraxNG/AxTraxPro Access Control Management
Software.
AC-825IP panels connect to the IP network using an onboard network module.
6.1.1. LAN and WAN Requirements
The devices can be connected to an IP network using any valid network address.
Figure 29: Connecting Multiple AC-825IP Panels to the AxTraxNG/AxTraxPro Server illustrates the connection of a
single AC-825IP to a computer via a LAN network.
AC-825IP Installation & User Guide
www.rosslaresecurity.com
37