EasyManuals Logo

Rosslare AC-825IP Installation & User Guide

Rosslare AC-825IP
39 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #37 background imageLoading...
Page #37 background image
5. In seven seconds or less, set all the DIP switches to OFF.
As the restore to factory defaults process continues, the red LED of the G bus flashes quickly.
6. Wait 90 seconds for the restore to factory defaults process to be fully completed.
When the restore to default process is complete, the red LED of the G bus flashes slowly for 5 seconds.
Then the panel will start the initialization process (at this time the panel is not available to operate).
When the initialization process is complete, the red LED of the G bus will continuously flash slowly.
6. Communications
Communication lines are used to upload and download information between the AC-825IP panel and the
AxTraxNG/AxTraxPro server using an IP network.
6.1. TCP/IP Network Connection
The computer running the AxTraxNG/AxTraxPro server can communicate with the access control panels via an IP
network. The connection settings are controlled within the AxTraxNG/AxTraxPro Access Control Management
Software.
AC-825IP panels connect to the IP network using an onboard network module.
6.1.1. LAN and WAN Requirements
The devices can be connected to an IP network using any valid network address.
Figure 29: Connecting Multiple AC-825IP Panels to the AxTraxNG/AxTraxPro Server illustrates the connection of a
single AC-825IP to a computer via a LAN network.
AC-825IP Installation & User Guide
www.rosslaresecurity.com
37

Other manuals for Rosslare AC-825IP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rosslare AC-825IP and is the answer not in the manual?

Rosslare AC-825IP Specifications

General IconGeneral
BrandRosslare
ModelAC-825IP
CategoryController
LanguageEnglish

Related product manuals