Operation
22 AC-F/G4x Family Installation and Programming Manual
auxiliary input is selected it de-activates the Norma/Secure mode code
(see Section 5.8).
4.3.3 From Normal to Bypass Mode
By default, there is no Normal/Bypass code. The Normal/Bypass code
must first be programmed to use this function (see Section 5.6 to
create/modify the Normal/Bypass code).
To change from Normal to Bypass mode:
1. Enter the Normal/Bypass code.
The Mode indicator flashes orange.
2. Press # to confirm the Mode change.
The Mode indicator turns orange.
4.3.4 From Bypass to Normal Mode
To change from Bypass to Normal mode:
1. Enter the Normal/Bypass code.
The Mode indicator flashes green.
2. Press # to confirm the Mode change.
The Mode indicator turns green.