3.4.8) Fuel pump (on 914 Series)
See Fig. 73-41.
Two electrical fuel pumps are included in each delivery.
Check of the fuel filter, see Line Maintenance 12-00-00 sec. 2.10.
â—† NOTE: The built-in screen on the suction side of the electric
fuel pumps cannot be replaced.
Carry out a visual inspection of the fuel pump.
â–  CAUTION : The fuel pump must not be disassembled, as there are
no spare parts available. If necessary, replace the
complete fuel pump.
In the event of a malfunction in the fuel system, the pump performance
and/or the current input of the fuel pump can be checked.
With a pressure difference of approx. 250 hPa, the fuel pump is
pumping at approx. 100 l/h.
The current input at this quantity is approx. 2 A.
â—† NOTE: These figures are reference values.