74-00-00
page 22
May 01/2007
Effectivity 912/914 Series
Edition 1 / Rev. 0
d02624
BRP-Rotax
Maintenance Manual
3.12) Measurement values for the ignition unit
The following measurement values can be checked at the appropriate point after
detaching the plug connections.
Generator coil
(on stator) yellow - yellow 0.1 to 0.8 Ω
Generator coil yellow - ground ∞
Charging coil
(on stator) red - ground 3.2 to 4.5 Ω
Trigger coil green/white - blue/yellow 115.0 to 123.0 Ω
Trigger coil new *
(with clamps) white/yellow - blue/yellow 220.0 to 250.0 Ω
Primary ignition coil
connection contact - ground 0.1 to 0.4 Ω
Secondary ignition coil
high voltage - High v. 6.1 to 6.7 kΩ
Resistance spark plug connector 4.4 to 6.0 kΩ
â—† NOTE: * Fitted in serial production from year 1995.
â—† NOTE: A check of the complete ignition unit is only possible on an
ignition test bench with an oscilloscope. This is especially
important if failure occurs only intermittently. In this case, send
the complete ignition unit to an authorized overhaul facility.

Table of Contents

Other manuals for Rotax OM-912

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rotax OM-912 and is the answer not in the manual?

Rotax OM-912 Specifications

General IconGeneral
BrandRotax
ModelOM-912
CategoryEngine
LanguageEnglish

Related product manuals