10.5) Measuring tools
Calliper rule, dial gauge indicator, micrometer, inner micrometer, inner fine
measuring device, feeler gauge, spring scale up to 50 kp (500 N)(112.5 lbf).
Stroboscope: BOSCH 0 684 100 308 or equivalent. Supply voltage 8 to 15
V. Flash triggering via inductive clampon pickup. Flashing
frequency 4500 rpm.
Multimeter: FLUKE series 70, series 80 or equivalent.
Electronic, 3 1/2 digit indication.
Current range 10 A.
Direct voltage range 200 V minimum.
Resistance range 200 Ω to 2 MΩ
Acoustic continuity tester.
Oscilloscope: TEKTRONIX 2225 or equivalent
2 channels
Analog
Sensitivity 5 mV to 5V/div
Frequency limit 50 MHz
■ CAUTION: When using these instruments, observe the manufacturer’s
instructions.