2.4) Connections for instrumentation
â–  CAUTION: Consult also the relevant sections on connections for
instrumentation in the latest Installation Manual.
2.4.1) Exhaust gas temperature display (optional)
The exhaust gas temperature is monitored by means of 4 sensors on
the exhaust manifold. The temperature display device is connected via
NiCrNi control lines.
On 912 Series: The manufacturer of the exhaust system must attach
or provide the connections M8x1 for installation of the
metalsheathed thermocouples, part no. 966370, in the
exhaust bends.
On 914 Series: The connection thread M8x1 for attachment of the
metalsheathed thermocouples, part no. 966370, are
already provided in the exhaust bends.