79-00-00
page 10
May 01/2007
Effectivity 912/914 Series
Edition 1 / Rev. 0
d02628
BRP-Rotax
Maintenance Manual
2.4) Magnetic plug
See the corresponding Maintenance Manual (Line Maintenance) for the respec-
tive engine type, 912 Series or 914 Series.
2.5) Drain plug
See the corresponding Maintenance Manual (Line Maintenance) for the respec-
tive engine type, 912 Series or 914 Series.
2.6) Connections for instrumentation
â–  CAUTION: Consult also the relevant section in the Installation Manual.
2.6.1) Oil pressure indication
Via an electric resistance pick-up attached on oil pump housing with
connection to indicating instrument.
2.6.2) Oil temperature indication
The sensor for the oil temperature is fitted in the oil pump housing. The
sensor is a thermo switch with changing internal resistance according
to oil temperature.