Legend to monitor display
(2) Rev counter display
(3) Throttle valve position
(4) Pressure difference between (8) and (9)
(5) LOG status ON/OFF
(6) Target pressure on basis of throttle valve position
(7) Target pressure on basis of pressure ratio between (9) and (10)
(8) effective target pressure input
(possibly reduced, e.g. by overspeeding, airbox temperature or too high pressure
ratio)
(9) Airbox pressure
(10) Ambient pressure
(11) Servo position
(12) not activated
(13) Target pressure reduction by exceeding of the max. airbox temperature
(14) Target pressure reduction by exceeding max. engine speed
(15) Airbox temperature
(16) Knocking signal (not activated)
(17) LOG actuation ON/OFF
(18) Software status
(19) Program identification
(20) Servo output %
(21) D factor
(22) I factor
(23) P factor