The bearings are tested by means of the pressure drop measuring
method.
â–  CAUTION: For this test, compressed air at approx. 2 bar (29 p.s.i)
and a testing device are needed.
Consisting of:
2 pressure gauges
1 orifice jet (inner diameter = 1 mm (.039 in.) / length = 3 mm
(.12 in.)
1 connecting nipple M12x1.5
for the thread in the middle section of the turbocharger
1 cover plate for the oil outlet
n.B. connecting hoses
Procedure:
Screw in the connecting nipple and close the oil outlet with the cover
plate.
Connect the pressure gauges together with the regulating valves.
Apply a constant pressure of 2 bar (29 p.s.i) to the connection
cable. The pressure drop must not exceed 50%.
(From 2 bar (29 p.s.i) to max. 1 bar (14.5 p.s.i))
â—† NOTE: For optimum results, the position of the shaft should
always be changed slightly during the check, i.e. the
shaft should be moved backwards and forwards in axial
and radial directions.

Table of Contents

Other manuals for Rotax OM-912

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rotax OM-912 and is the answer not in the manual?

Rotax OM-912 Specifications

General IconGeneral
BrandRotax
ModelOM-912
CategoryEngine
LanguageEnglish

Related product manuals