4 x Set-up and installation
FA ROTEX HPSU compact 4 - 06/2015
15
4 Set-up and installation
4.1 Dimensions and connections
4.1.1 ROTEX HPSU compact 304/308
WARNING
Cooling systems (heating pumps), climate co
ntrol systems and heating devices that have been set up and installed incor-
rectly can both endanger life and health of peop
le and be impaired in their function.
Ɣ Work o
n the ROTEX HPSU compact (such as setup, servicing, connection and initial start-up) is only to be carried out
by persons who are authorised and who have successfully completed qualifying technical or vocational training and
who have taken part in advanced training sessions recognised by the relevant responsible authorities for the specific
activity. These include in particular certified heating engineers, qualified electricians and HVAC specialists, who
because of their professional training and expert knowledge, have experience in the professional installation and
maintenance of heating, cooling and air conditioning systems and heat pumps.
1 Solar - feed
2 Cold water
3 Hot water
4 Heating feed
5 H
eating return flow
6 Connection coolant gas line
7 Connection coolant fluid line
8 Solar - flow (only type ... BIV)
9 Solar - return (only type ... BIV)
A Front
BBack
Fig. 4-1 Connections and dimensions ROTEX HPSU compact 304/308 (in general)