Control Definition
2-6 HP6A Manual
The following is a list of factory settings:
Address
Code
Description
Factory Setting Actual Setting
0 0 – 5% of Motor Load .012
1 5 - 10% of Motor Load .012
2 10 – 15% of Motor Load .012
3 15 – 20% of Motor Load .012
4 20 – 25% of Motor Load .012
5 25 – 30% of Motor Load .012
6 30 – 35% of Motor Load .061
7 35 – 40% of Motor Load .086
8 40 – 45% of Motor Load .098
9 45 – 50% of Motor Load .110
10 50 – 55% of Motor Load .122
11 55 – 60% of Motor Load .135
12 60 – 65% of Motor Load .135
13 65 – 70% of Motor Load .147
14 70 – 75% of Motor Load .172
15 75 – 80% of Motor Load .172
16 80 – 85% of Motor Load .184
17 85 – 90% of Motor Load .208
18 90 – 95% of Motor Load .221
19 95 – 100% of Motor Load .221
20-29 Not Used
30 0 – 5 Strokes Per Minute 1.56
31 5 – 10 Strokes Per Minute 1.56
32 10 – 15 Strokes Per Minute 1.56
33 15 – 20 Strokes Per Minute 1.19
34 20 – 25 Strokes Per Minute .77
35 25 – 30 Strokes Per Minute .67
36 30 – 35 Strokes Per Minute .57
37 35 – 40 Strokes Per Minute .47
38 40 – 45 Strokes Per Minute .37
39 45 – 50 Strokes Per Minute .37
40 50 – 55 Strokes Per Minute .25
41 55 – 60 Strokes Per Minute .19
42 60 – 65 Strokes Per Minute .18
43 65 – 70 Strokes Per Minute .13
44 70 – 75 Strokes Per Minute .11
45 75 – 80 Strokes Per Minute .11
46 80 – 85 Strokes Per Minute .07
47 85 – 90 Strokes Per Minute .01
48 90 – 95 Strokes Per Minute .01
49 95 – 100 Strokes Per Minute .01
50-61 Not used
62 Plateau Load Setting 5
63 Deadband 10
64 Minimum Motor Load Setting 1.2
65 Maximum Motor Load Setting 6.3
66 Short stroke Time Adjustment .380
67 Counter N/A N/A
68 Starting Target Load 50
69 Factory Table Selection 1
70 Plateau Stroke Setting 4