39
after modification. Please do not set a wrong time, it may cause that the date will not
be automatically accumulated. Press the encoder potentiometer to return, and the
set value will be saved automatically. Upd.R. is the refresh rate of read back voltage
and current in the main page, you can set it to low, middle and high. Press encoder
potentiometer to return and save the settings.
1.4.2.6 Main Page Display Style Setting
Main interface display style setting operation videohttps://youtu.be/f51VDiY2VHE
You can press SHIFT + MENU to enter the system setting menu, and then press
the right button to enter the main page style setting menu as shown above. Press
ENTER and then use direction button to set classic style or curve style. The pattern in
red is the style being chosen. Press the encoder potentiometer to return and save
the settings. The classic style is the system default style, it shows the voltage, current
and power in large font. The curve style is as shown above, the color of the three
curves corresponds to the output voltage, current and power. D is the scale of the
ordinate, Press “ENTER” to start or pause the curve, and rotate the encoder
potentiometer to scale the ordinate of the curve.
1.4.2.7 Storage Data Setting
Data group setting in manual operation videohttps://youtu.be/i1kTeurS13I
You can press SHIFT + MENU to enter the system setting menu, and then press
the right button twice to enter the data storage setting menu as shown below, press
ENTER to enter the setting menu, the icon in red is the chosen data group, press the
direction button to select data group number. Press I-SET” button to set the storage
output current value, then rotate the encoder potentiometer the adjust the output
value, press the direction button to move the cursor. You can also set the value with
keypad, press ENTER to confirm. If you set the wrong value, you can press the
encoder potentiometer to cancel. Press V-SET button to set the storage output
voltage value, the operation method is similar to storage output current setting.
Press “SHIFT+ I-SET” button or “SHIFT”+ V-SET button to set the storage
over current protection/ storage over voltage protection value. The operation