5 INSTALLATION
5.1 Cautions
The appliance cannot be installed in
external areas. Avoid installing it in areas
where the temperature is lower than
+2°C or higher than 32°C and in
particularly humid or dusty places. It should
neither be installed in places where water
jets are used for cleaning operations nor
where there is a risk of fire or explosion.
Make sure that the installation place is compatible with the following
specifications, before unpacking the appliance:
the electric socket or the all-pole switch which the appliance is
connected to must be easily accessible for the user, so that the user
will easily disconnect the machine from the electric mains when
necessary;
the socket voltage must correspond to that indicated on the
appliance data plate.
the gradient of the supporting surface should NOT exceed 2°;
Check that the size and strength of the
surface where the machine is installed are
appropriate to safely bear it.
For a correct and ergonomic use of the
machine, it is recommended to install it
onto a surface which is at least 1 m high.
The appliance must be installed on a
horizontal surface.
The appliance must only be installed in places where it can be used
and serviced by qualified staff only.
If the appliance needs to be positioned close to a wall, it is necessary
to leave a space of at least 8 cm between the appliance’s back and the
wall, in order to make sure that the air outlet grill at the back of the
appliance is unobstructed.