HYBRID SOLAR INVERTER INSTRUCTION MANUAL
5.5
Expo limit wiring schematic
Working Modes
5.6
Expo Limit Setting
Self-consumption Mode: When the solar is sucient, electricity generated by photovoltaic
system will be supplied to load rst, the surplus energy will be stored in batte, then the excess
electricity will be expoed to the grid. When the solar is sucient, the batte will release
electricity to supply load.
Back-up Mode: Reseed Backup SOC setting value can be adjusted, when batte SOC is less
than reseed SOC value, batte can only be charged, until SOC reaches reseed value, the
batte will be stopped charging; when SOC is larger than SOC setting value, batte will
behave as Self-use mode.
Time-of-use Mode: Batte charging period and discharging period can be set, during
charging period, batte can only be charged, while in discharging period, batte can only be
discharged, the rest of the period, batte will behave as Self-use mode.
3635
5.5.1
Selecting working
modes procedures
5.5.2
Working modes
5.6.1
introduction
Enter the main page of local connection and click on Expo limitation setting, enter the
APP Setting
password “201561”.
GridMain Meter
I
Sma Meter A(White) A(Blue)
N
I
L
PV Array
Solar inveer
On-grid Load
CT
3 4 -
B
L N
A+
5 6