17
Do not use an installation with a leak
before it has been inspected and
repaired by a competent person.
If a leak is detected, close the main
LPG supply valve and do not use LPG
equipment.
Do not use flames to search for
leaks
The LPG system should be leak tested before each use as follows:
IV- SAFETY
Do not change the LPG system of the craft. Installation, modifications and maintenance must be carried out by a competent
person. Check the system at regular intervals or those set according to national requirements.
Use the bubble leak detector according to the manufacturer's instructions. If an LPG leak is detected or suspected, immediately take the
following measures:
- Switch off the LPG supply at the main feed valve or valves, close the cylinder taps;
- Switch off naked flames and other sources of ignition (heating appliances, cooking appliances, lights, etc.);
- Do not switch on any electrical switch;
- Evacuate the area, if possible.
Repair before further use
The tests above carried out by users cannot replace a check of the LPG system by a competent person.