Index revision : C - November 2017 36 7030
6.9. High Voltage Connection
6.9.1. Preparing the high voltage connection
WARNING : Ensure that insulation is not
damaged. Any scratch or start of a cut on the
surface of the insulating material will result in
breakdown of the high voltage cable.
Step 1: Strip back approximately 22.5 cm of
the purple insulation from high voltage
cable with a wire stripper. A “Stanley knife”
type cutting tool must not be used.
Next strip back approximately 19 cm of the
semi-conductive sheath (black sleeve)
and cut it with cutting pliers.
Step 2: Insert seal and clamp into the nut.
Step 3: Slide the nut assembly, split cone
and the cable-securing adapter onto the
cable. Then screw the nut onto the
adapter.
DES03696
Cable-securing
adapter
High voltage
cable
Supporting
Nut
Split
cone
End fitting
Clamp Protective hose
Step 1
Step 2
Step 3

Table of Contents