Index revision : C - November 2017 39 7030
7. Cleaning Procedures
At regular intervals during frequent use, and at the end of each cycle:
Stop the atomizer and switch off power supply.
Always refer to the health and safety instructions before carrying out any work see § 1.4 page 7.
WARNING : Always wear safety goggles.
Whenever solvent is handled, rubber gloves must be worn.
Work in a well-ventilated area whenever solvent is used.
WARNING : Prior to cleaning, it is essential to wipe the atomizer using a cloth soaked in water,
a soft brush and an approved cleaning product. Do not use a manual solvent gun.
WARNING : Do not soak the turbine in solvent.
The atomizer and its components must never be sprayed with solvent or water under any
circumstances, whether at high or low pressure.
WARNING : SAMES KREMLIN disadvises the use of anti-static plastic films to protect bodies
and insulating covers of the atomizers. These films are conductive and can short-circuit the high
voltage.
SAMES KREMLIN forbids the use of adhesives on the insulating parts of the atomizers. The
glue of the adhesives is conductive and thus can short-circuit the high voltage.
SAMES KREMLIN also forbids the use of absorbent textile cover to protect bodies and insu-
lating covers of atomizers. Textile covers retain the cleaning products and paint what can gen-
erate problems of high voltage (drilling, ionization, degradation of the material...).
Thus, SAMES KREMLIN recommends the use of insulating grease for protection of the
atomizers.
In any case, insulating protection means must be used to prevent the slightest risk of current
overconsumption.
This is why, insulating protection means must be renewed on a regular basis.
Procedure Components Frequency
A Outer cover, outside of bell cup 8 hours
B
Bell cup, shaping air shroud, outer cover, outside
of injector, outside of bell cup
120 hours