EasyManua.ls Logo

Samson 3374 - Ordering Spare Parts and Operating Supplies

Samson 3374
104 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9-10 EB 3018 EN
Servicing
Removing Type5827 Electric Actuator with-
out fail-safe action
1. Put the regulator out of operation (see
the 'Decommissioning' section).
2. Unscrew the coupling nut (11) of the
electric actuator from the valve. Remove
the actuator.
Mounting Type5827 Electric Actuator
without fail-safe action
1. Place the electric actuator on the valve
and fasten tight the coupling nut (11).
Observe the specied tightening torques
(see 'Tightening torques' in Annex).
2. Put the regulator back into operation (see
the 'Start-up' section).
Removing Type3374 Electric Actuator
1. Put the regulator out of operation (see
the 'Decommissioning' section).
2. Undo and remove the clamps of the stem
connector (1.2).
3. Unscrew the hex nut (1.3) and remove
the electric actuator from the valve.
Mounting Type3374 Electric Actuator
1. Place the electric actuator on the valve
and fasten tight the hex nut (1.3). Ob-
serve the specied tightening torques
(see 'Tightening torques' in Annex).
2. Position the stem connector clamps (1.2)
and screw them tight (see 'Tightening
torques' in Annex).
3. Put the regulator back into operation (see
the 'Start-up' section).
9.4 Ordering spare parts and
operating supplies
Contact your nearest SAMSON subsidiary
or SAMSON's After-sales Service for infor-
mation on spare parts, lubricants and tools.
Spare parts
See Annex for details on spare parts.
Lubricants
Contact SAMSON's After-sales Service for
more information on lubricants.
Tools
Contact SAMSON's After-sales Service for
more information on tools.