Product Specifications
2-24 Samsung Electronics
Indoor Unit(cont.)
QCeiling type
Model
AVXTFH056E6
ND056CH666
AVXTFH071E6
ND071CH666
Power Supply ø/V/Hz 1/220~240/50 1/220~240/50
Mode*
1)
HP / HR HP / HR
Performance
Capacity
Cooling*
2)
kW 5.6 7.1
Btu/h 19,100 24,200
Heating*
3)
kW 6.3 8.0
Btu/h 21,400 27,200
Condensate (with High fan speed) Liters/h 2.87 2.87
Power
Input W 72 120
Running Current A 0.33 0.6
Sound Level Sound Pressure (High/Low)*
4)
dB(A) 36 / 32 36 / 32
Fan
Type - Sirocco Fan Sirocco Fan
Motor
Model - YSK140-60-4B YSK140-60-4B
Type - Non Feedback SSR Non Feedback SSR
Output W *5) *5)
Airflow Rate
Cooling (High) m
3
/min 16.5 16.5
Heating (High) m
3
/min 20.0 20.0
Refrigerant
Type - R410A R410A
Control Method - EEV EEV
Temperature Control - Micom&Thermistors Micom&Thermistors
Safety Devices - Fuse Fuse
Piping
Connections
Liquid (Flare) ø, mm 9.52 9.52
Gas (Flare) ø, mm 15.88 15.88
Drain ø, mm VP25 (OD 32,ID 25) VP25 (OD 32,ID 25)
Weight
Net Weight kg 31.0 31.0
Shipping Weight kg 39.0 39.0
Dimensions
Net Dimensions (W x H x D) mm 1,100x199x600 1,100x199x600
Shipping Dimensions (W x H x D) mm 1,330x330x730 1,330x330x730
Functions
Auto Restart - O O
Auto Swing - X X
Group/Individual Control - O O
External Contact Control - O O
Trouble Shooting by LED - X X
Standard
Accessories
Installation Manual - O O
Operation Manual - O O
Pattern Sheet for Installation - X X
Flexible Drain Hose - O O
Filter / Safety Grille - Filter (Washable) Filter (Washable)
Optional
Accessories
Wireless Remote Controller - MRK-A01 MRK-A01
Wired Remote
Controller
Simplified - MWR-TH01 MWR-TH01
Standard - MWR-WS00 MWR-WS00
Premium - MIM-B14 MIM-B14
External Contact Interface Module - MDP-E075SEE MDP-E075SEE1
*1) Mode
- HP : Heat Pump, HR : Heat Recovery
*2) Norminal cooling capacities are based on;
- Indoor temperature : 27˚C DB, 19˚C WB
- Outdoor temperature : 35˚C DB, 24˚C WB , Equivalent refrigerant piping : 7.5m , Level differences : 0m
*3) Norminal heating capacities are based on;
- Indoor temperature : 20˚C DB, 15˚C WB
- Outdoor temperature : 7˚C DB, 6˚C WB , Equivalent refrigerant piping : 7.5m , Level differences : 0m
*4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
*5) Specifications may be subject to change without prior notice for product improvement.