4.Troubleshooting
UnitItemMax.LifeDefaultThreshold
Yellow300K10%5~30%
Magenta300K10%5~30%
Cyan300K10%5~30%
DeveloperUnit
Black300K10%5~30%
WasteTonerContainerWasteTonerContainer20KNearFullNA
Finisher
FinisherStapler
Cartridge
NANearEmptyNA
ITB150K(PMCount)5%2%~10%
Transfer
T2Roller150K(PMCount)5%3%~10%
FuserFuser150K(PMCount)10%5%~20%
P/upRollerMP150K(PMCount)10%5%~20%
P/upRollerKit-tray1150K(PMCount)10%5%~20%
P/upRollerKit-tray2150K(PMCount)10%5%~20%
P/upRollerKit-tray3150K(PMCount)10%5%~20%
Roller
P/upRollerKit-tray4150K(PMCount)10%5%~20%
DADFRollerAssemblyADFRoller150K(PMCount)10%5%~20%
4.5.3.3.SoftwareVersion
•Information>SoftwareVersion
Thismenudisplaysalltheversionofthesoftwareinstalledinthesystemindetail.
4.5.3.4.ServiceHours
•Information>ServiceHours
Thismenudisplaysthreeitems,“PoweronHours”,“LowPowerHours”and“PowerSaveHours”.
-PoweronHours:Itindicatesthehoursofsystempoweronsincetherstbootingofthesystem.
-LowPowerHours:Itindicatesthehoursofsystemlowpoweronsincetherstbootingofthesystem.
-PowerSaveHours:Itindicatesthehoursofsystempowersavesincetherstbootingofthesystem.
4.5.3.5.FaultLog
•Information>FaultLog
Thismenudisplaysfaultsoccurredwhilethesystemwasoperating.
Pressingclearbuttonwillclearallthesavefaultlogofthesystem.