Samsung CLX-8640ND - Sensor Failure: #A3-3111. Turn off then On. Call for Service if the Problem Persists; Sensor Failure: #A3-3112. Turn off then On. Call for Service if the Problem Persists; Sensor Failure: #A3-3113. Turn off then On. Call for Service if the Problem Persists; Sensor Failure: #A3-3114. Turn off then On. Call for Service if the Problem Persists

Samsung CLX-8640ND
441 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4.Troubleshooting
ErrorCode
A3–3111
A3–3112
A3–3113
A3–3114
Errormessage
SensorFailure:#A3-3111.Turnoffthenon.Callforserviceiftheproblempersists.
SensorFailure:#A3-3112.Turnoffthenon.Callforserviceiftheproblempersists.
SensorFailure:#A3-3113.Turnoffthenon.Callforserviceiftheproblempersists.
SensorFailure:#A3-3114.Turnoffthenon.Callforserviceiftheproblempersists.
Symptom
TheNCsensorinthefuserunitisdefective./Thesensorsignalisabnormalduetoadefectiveharness.
Troubleshootingmethod
A3–3111:CenterNCsensorisinshortstatus.
A3–3112:CenterNCsensorisinopenstatus.
A3–3113:SideNCsensorisinshortstatus.
A3–3114:SideNCsensorisinopenstatus.
1)EnterSVCmode.Executesensortesttocheckthesensoroperation.
(Diagnostics>EngineDiagnostics>EngineTestRoutines)
109-0000:FuserTemperatureA
109-0010:FuserTemperatureB
2)RemovethefuserunitanddisassembletheNCthermistor.
3)Measuretheresistancevalueofthethermistor.
Side:1404–001718
Center:1404–001719
Ifthemeasuredvalueisoutof307KΩ~430KΩ@25,replacethethermistor.
4)Installthefuserunitafterreplacingthethermistor.
5)Ifthethermistorisnormal,replacetheharnessbetweenthefuserunitandmainboard.(JC39–01746A)
4-109Copyright©1995-2013SAMSUNG.Allrightsreserved.