EasyManua.ls Logo

Samsung CLX-8640ND - Sensor Failure: #A3-3210. Turn off then On. Call for Service if the Problem Persists; Sensor Failure: #A3-3211. Turn off then On. Call for Service if the Problem Persists; Sensor Failure: #A3-3212. Turn off then On. Call for Service if the Problem Persists; Error Message

Samsung CLX-8640ND
441 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4.Troubleshooting
ErrorCode
A3–3210
A3–3211
A3–3212
Errormessage
SensorFailure:#A3-3210.Turnoffthenon.Callforserviceiftheproblempersists
SensorFailure:#A3-3211.Turnoffthenon.Callforserviceiftheproblempersists
SensorFailure:#A3-3212.Turnoffthenon.Callforserviceiftheproblempersists
Symptom
Innertemperaturesensorisdefective.
Troubleshootingmethod
A3–3210:Innertemperaturesensorvalueisabnormal.
A3–3211:Innertemperaturesensorisinshortstatus.
A3–3212:Innertemperaturesensorisinopenstatus.
1)EnterSVCmode.Executesensortesttocheckthesensoroperation.
(Diagnostics>EngineDiagnostics>EngineTestRoutines>109-0012InnerTemperature)
2)Removetherearcoverafterremoving7screws.
3)Checkiftheinnertemperaturesensorharnessisconnectedcorrectly.
4)Removetheharness.Measuretheresistancevalueoftheconnectoratbothends.(C36_16,CN36_17)
Ifthevaluesisnotin10KΩ±1%(@25),replacethephotosensor(1404-001417).
5)Ifthesensorisnormal,replacethemainboard(JC92–02516A).
4-111Copyright©1995-2013SAMSUNG.Allrightsreserved.