4.Troubleshooting
►ErrorCode
A1–2511
A1–2512
A1–2513
►Errormessage
MotorFailure:#A1-2511.Turnoffthenon.Callforserviceiftheproblempersists
MotorFailure:#A1-2512.Turnoffthenon.Callforserviceiftheproblempersists
MotorFailure:#A1-2513.Turnoffthenon.Callforserviceiftheproblempersists
►Symptom
BlackOPCmotoroperationisabnormal.
►Troubleshootingmethod
•A1–2411:BlackOPCmotorisstoppedbutmachinerecognizesitasoperational.
•A1–2412:BlackOPCmotorisnotoperatedforprint-job.
•A1–2413:BlackOPCmotorisoperatingbutmachinerecognizesstatusas"Stopped".
1)Turnthemachineoffthenon.Iftheerrorpersists,turnthemachineoffagain.
2)Openthefrontcover.Checkifthereareanyforeignsubstancesorpaperaroundblackdrumdriveunit.
3)Turnthemachineon.Iftheerrorpersists,turnthemachineoffagain.
4)Removetherearcoverafterremoving7screws.
5)CheckiftheblackOPCmotorconnectorisconnectedcorrectly.
6)IftheconnectionisOK,turnthemachineon.EnterSVCmode.SelectblackOPCmotortest.
(Diagnostics>EngineDiagnostics>EngineT estRoutines>100–0044)
Checkthemotoroperation.
a)Ifthemotorisnotoperational,
Copyright©1995-2013SAMSUNG.Allrightsreserved.4-96