4.Troubleshooting
ErrorCode
S5–3111
Errormessage
UISystemFailure#S5-3111:Turnoffthenon.
Symptom
CommunicationerrorbetweenmainboardandOPEboardhasoccurred.
Troubleshootingmethod
1)Removetherearcover.
(Referto3.3.2RearCover.
)
2)CheckiftheOPEcableisconnectedtothemainboardcorrectly.
3)RemoveanddisassembletheOPEunit.
(Referto3.3.20OPEunit.
)
4)CheckiftheOPEcableisconnectedtotheOPEboardcorrectly.
5)IftheconnectionisOK,replacethemainboard(JC92–02516A).
Copyright©1995-2013SAMSUNG.Allrightsreserved.4-230