4.Troubleshooting
ErrorCode
S2–1211
Errormessage
EngineSystemFailure:#S2-1211.Turnoffthenon
Symptom
CommunicationerrorbetweentheASIConmainboardandmicrocontrollerIChasoccurred.
Troubleshootingmethod
1)Turnthemachineoffandon.
2)Iftheproblempersists,turnthemachineoffagain.
3)Removetherearcover.
(Referto3.3.2RearCover.
)
4)Replacethemainboard(JC92-02516A)
(Referto3.3.7MainBoard.)
5)Assembletherearcover.Turnthemachineon.
4-223Copyright©1995-2013SAMSUNG.Allrightsreserved.