4.Troubleshooting
•Diagnostics>Adjustment>PrintAdjustment>Magnication
PurposeTocorrectmagnicationofprint-outsmanually.
OperationProcedure
1)Press“V erticalMagnication”or“HorizontalMagnication”
2)Horizontalmagnication(c):Ifthecurrentvalueissmallerthanthespecication,press
”+”.Otherwise,press“-”.
3)Verticalmagnication(d):Ifthecurrentvalueissmallerthanthespecication,press”+”.
Otherwise,press“-”.
Examp le
Cas es
Vertica l
Ad jus tme nt
Ho rizonta l
Ad jus tme nt
= 189 mm +
VericationPrintoutandmeasureifthelengthofvertical(400mm)andhorizontalline(277mm)intheprint-out
arecorrect.
Specicationc:190mm,±1.5mm(A3)
d:277mm,±1.5mm(A3)
ReferenceScannerA/SChart
•Diagnostics>Adjustment>PrintAdjustment>ImagePosition
PurposeTocorrectimagepositionofprint-outsmanually.
OperationProcedure
1)Selectatrayrequiredadjustment.
2)Changetheadjustmentvaluewitharrowbutton.“+”valuewillmovetoTail-Edgewhile
“-”valuewillmovetoLead-Edge.
Exa mple
Cases
Simple x
Leading
Edge
Simple x
Side Edge
VericationPrintoutandcheckifallthepositionofscalemarks(a,b)intheimagearelocatedwithinthespecied
limit.
Specicationa,b:10mm,±1.5mm
ReferenceScannerA/SChart
•Diagnostics>Adjustment>PrintAdjustment>PrintTestPattern
Thismenusprintsthetestpattern.
Copyright©1995-2013SAMSUNG.Allrightsreserved.4-56