s15nmdl3sm-REV1207 Model S15 Non-Metallic Page 31
This optional 8 foot long (244 centimeters) Ground
Strap (920-025-000) is available for easy ground
connection.
To reduce the risk of static electrical sparking, this
pump must be grounded. Check the local electrical
code for detailed grounding instruction and the type
of equipment required.
Take action to prevent static
sparking. Fire or explosion can
result, especially when handling
flammable liquids. The pump,
piping, valves, containers or
other miscellaneous equipment
must be grounded.
WARNING WARNING
One eyelet end is fastened to the pump hardware.
The other end is installed to a true earth ground.
Grounding The Pump
To be fully groundable, the pumps must be ATEX
Compliant. Refer to pump data sheet for ordering.