Mechanical Disassembly
9-1. Optical Unit Assy removal-1
1. Remove both of the Lamp Assy upward.
2. Remove 2 screws-A (T3x8) each on the Lamp Duct.
A
A
A
A
Lamp2
Lamp1
9-2. Optical Unit Assy removal-2
1. Remove 1 screw-B (T3x8) each on the Lamp Socket and remove them.
2. Remove 1 screw-C (T3x8) each on the ID Connect board.
3.
Remove 1 screw-D (T2.6x8) and remove the Thermal Protectors (SW901).
Spacer
D
T2.6x8
SW901
Printed marker is
facing out side.
B C
C
B
D
Lamp2
socket
ID connect
board
SW901
Lamp1
socket
Groove
Thermal protector (SW901) removal