-41-
Optical Parts Disassembly
4-1. Condenser Lens Assy removal
1. Remove 2 screws-A (M2.5x5) and slide the Condenser Lens Assy in the
arrow direction and pull it up.
Condenser lens
Condenser
lens assy
A
Condenser
lens
Spacer
T3x8
A

Table of Contents