Sanyo PLC-WTC500L - Lens Shift Assy Removal

Sanyo PLC-WTC500L
180 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
-32-
Mechanical Disassembly
10-1. Lens Shift Assy Removal
1. Remove 4 screws-A (M3x6) and remove the Lens Shift Assy.
(Before removing the Lens Shift Assy, remove the LCD Panel/Prism Assy
first. Refer to the optical parts disassembly.)
A
A
A
A
Lens
shift assy
T3x5
T3x5
Lens shift sen-
sor-X board
Lens shift sen-
sor-Y board
Lens shift
motor (X)
Lens shift
motor (Y)
11-1. Lens Cover Assy removal
1. Remove 2 screws-A (T3x8) and remove the Lens Cover Assy.
2. Unhook 2 hooks and disassemble the Lens Cover Assy.
3. Remove each 1 screw-B (T3x8) and remove the trigger boxes.
T3x8
T3x8
A
A
B
B
Release button
Spring
Hooks
Trigger box
Trigger box