-92-
Chassis Description
Error Error Code
Error Infomation
(See Powe Failure Detection System)
Error Code
Error Infomation
(See Powe Failure Detection System)
Normal 0 -
Power Failure
1000
PJ_NET, S5/3.3V
1017
FAN1, FANLOCK
1001
MAIN/AV, S10/5V
1018
FAN2, FANLOCK
1002
MAIN, S-6V
1019
FAN3, FANLOCK
1003
FPGA, S1.2V
1020
FAN4, FANLOCK
1004
KS, S1.8V
1021
FAN5, FANLOCK
1005
KS, S2.5V
1022
FAN6, FANLOCK
1006
KS, S3.3V
1023
FAN7, FANLOCK
1007
HDMI, 1.2V
1024
FAN8, FANLOCK
1008
RELAY, 12V
1025
FILTER, DET
1009
MAIN, 3.3V
1026
MOTOR, TIMEOUT
1010
MAIN, 5V
1027
PRESS, ERROR
1011
MAIN, 15/12/9V
1028
FPGASW, CONFIG
1012
GAMMA, 1V
1029
SHUTTER, ERROR
1013
AV, S3.3V
1030
MIRROR, ERROR
1014
AV, 15V
1015
AV, S-5V
1016
AV, S9V
Temperature Error
2000 Sensor A detects abnormal temperature. (TH901)
2001 Sensor A fails measurement. (TH901)
2100 Sensor B detects abnormal temperature. (IC8841)
2101 Sensor B fails measurement. (IC8841)
2102 Sensors B-A temperature error.
2200 Sensor C detects abnormal temperature. (IC8871)
2201 Sensor C fails measurement. (IC8871)
2202 Sensors C-A temperature error.
Lamp Error
3000 Lamp1 fails on
3001 Lamp2 fails on
3002 Lamp1 goes out
3003 Lamp2 goes out
3004 Communication Error on Lamp1
3005 Communication Error on Lamp2
System Error 4000
FPGASW, CONFIG
Shutter Error 5000
SHUTTER, ERROR
Filter Error 6000 Filter clogged
Error Log
This projector provides the error history log function. To
check the logs, you need to enter the service mode and
select Group No. "220" and Item No. "0" to "49". The error
code is displayed on the Data column. The description of
the error code is listed on the table below.
* How to enter the service mode and select the group, item
and data value, see "Service Adjustment Menu Opera-
tion".
Group
No.
Item
No.
Data
(Error Code)
220 0
1
2
3
:
:
49
✻
<- Latest Error
✻
✻
✻
:
:
✻
How to reset the Error Log
1. Enter the Service Mode, and select Group No. "220" and Item No. "50".
2 The history log will be reset when the Data Value is set to "10". The value automatically returns to "0".
* How to enter the service mode and select the group, item and data value, see "Service Adjustment Menu Operation".