-43-
Optical Parts Disassembly
A
A
B
B
6-1. Optical Parts in the Optical Unit removal
1. Remove 2 screws-A (T3x10) and unhook 4 hooks-B and take the Optical
Unit Top off.
Mirror(B)
Condenser lens(B)
Dichroic mirror(B)
Integrator lens(Out)
Integrator lens(In)
Mirror(R)
Condenser lens(R)
Mirror(R)
Relay lens(In)
Optical filter
Polarized glass(IN/GB)
Condenser lens(G)
Dichroic mirror(G)
PBS