-64-
Electrical Adjustment
Grp / No. Item Function Range Initial Note
20 0 - 10 0
21 Lamp Warning Time (NORMAL) 1-16 5
22 Lamp Warning Time (ECO) 1-16 6
23 Lamp Warning Time (HIGH) 1-16 4
50 Lamp Replacement Display 1:On 0:Off 0 - 1 1
51 Filter Warning Display 1:On 0:Off 0 - 1 1
52 Lamp Counter Reset Times Read only 0 - 255 0
53 Filter Counter Reset Times Read only 0 - 255 0
54 Factory Default Executed Times Read only 0 - 255 0
55 Motor Operation Stop 0: Enable 1: Disable 0 - 1 0
56 Menu Position (X) X Offset 0 - 1024 0
57 Menu Position (Y) Y Offset 0-1024 0
58 Lamp Go Out Lamp goes out 0 - 1 0
70 ADC Device Select for Analog PC 0 = ISL51002, 1 = PW392 AFE 0 - 1 0
71 ADC Device Select for Component 0 = ISL51002, 1 = PW392 AFE 0 - 1 1
72 Component/RGB SW
Auto Component/RGB Switch 0: Disable, 1: Enable
Disable G200-70/71 if this function is set to "Enable".
0 - 1 1
80 Destination Language Set at Shipping 0:English 1:Japanese 0 - 1 0
100 Disable Auto Picture Control 0 : Normal operation 1 : Auto Picture Control Off 0-1 Initial: 1 Shipping 0
201 Option (Signal) Not Used
0 FrameLock Option Frame Lock Setting 0: OFF, 1: Normal (Auto) 0 - 1 1
1 Dither Enable 0: Disable 1: Enable 0 - 1 1
204 Simulation mode
0 PW392C Enable 0: Off, 1: On 0 - 1 0
1 PW610 Enable 0: Off, 1: On 0 - 1 0
210 Lamp Contorl
0 Dimmer SW 0:Auto 1:Manual 0 - 1 0
1 Manual Control
Lamp Power Manual Control (DIMMER_CTRL_LEVEL
0(Dark)~15(Bright))
0 - 15 0
2 DIMMER_CTRL_LEVEL1 Y Level1 Data for Dimmer 0 - 255 7
3 DIMMER_CTRL_LEVEL2 Y Level2 Data for Dimmer 0 - 255 14
4 DIMMER_CTRL_LEVEL3 Y Level3 Data for Dimmer 0 - 255 21
5 DIMMER_CTRL_LEVEL4 Y Level4 Data for Dimmer 0 - 255 28
6 DIMMER_CTRL_LEVEL5 Y Level5 Data for Dimmer 0 - 255 35
7 DIMMER_CTRL_LEVEL6 Y Level6 Data for Dimmer 0 - 255 42
8 DIMMER_CTRL_LEVEL7 Y Level7 Data for Dimmer 0 - 255 49
9 DIMMER_CTRL_LEVEL8 Y Level8 Data for Dimmer 0 - 255 56
10 DIMMER_CTRL_LEVEL9 Y Level9 Data for Dimmer 0 - 255 63
11 DIMMER_CTRL_LEVEL10 Y Level10 Data for Dimmer 0 - 255 70
12 DIMMER_CTRL_LEVEL11 Y Level11 Data for Dimmer 0 - 255 77
13 DIMMER_CTRL_LEVEL12 Y Level12 Data for Dimmer 0 - 255 84
14 DIMMER_CTRL_LEVEL13 Y Level13 Data for Dimmer 0 - 255 91
15 DIMMER_CTRL_LEVEL14 Y Level14 Data for Dimmer 0 - 255 98
16 DIMMER_CTRL_LEVEL15 Y Level15 Data for Dimmer 0 - 255 105
17 DIMMER_AVERAGE_POINT Y Average Point 1 - 16 4
18 DIMMER_AVERAGE_DATA Y Average Data (Read only) - -
19 DIMMER_LEVEL_AUTO Current Y Level (Read only) - -
20 DIMMER_LEVEL_NORMAL Dim Level at Normal 0 - 15 8
21 DIMMER_LEVEL_ECO Dim Level at Eco 0 - 15 0
23 VOLTAGE_LEVEL Lamp Voltage (Read only) - -
24 DIMMER_LEVEL_HIGH Dim Level at High 0 - 15 15
220 Projector Error Log
0 Warning_Log_1 Latest Error log 0 - 32767 0
: : : : :
49 Warning_Log_50 50th Error log 0 - 32767 0
50 Warning_Log Reset Log is cleared when the value is set to 10. 0 ~ 10 0
235 Shutter
0 PRE_MOTION Shutter Warm - up Operation (0: Yes, 1: No) 0 - 1 Initial: 1 / Shipping: 0
1 CMP_TRM Chattering Detecting Term 0 - 32767 7000
2 OUT_DLY_TRM Output Term 0 - 32767 15000
3 CMP_CHK_CNT Count of Information Sync 0 - 15 0
4 OPEN_DLY Open Output Delay 0 - 63 0
5 CLOSE_DLY Close Output Delay 0 - 63 0
6 Position Check Time Position Check Time 1 - 255 50