-67-
Electrical Adjustment
Grp / No. Item Function Range Initial Note
10 Filter 2nd Cartridge Scroll Factor 1
2nd Filter Cartridge Scrolling Factor at N times Scrolling (N:1-10)
0: Manual Scrolling with OSD Menu
1: Auto Scrolling detecting by Filter Clogged
2: Auto Scrolling detecting by specified maximum used time per
a sheet
0 - 255 255
11 Filter 2nd Cartridge Scroll Factor 2 0 - 255 255
12 Filter 2nd Cartridge Scroll Factor 3 0 - 255 255
13 Filter 2nd Cartridge Scroll Factor 4 0 - 255 255
14 Filter 2nd Cartridge Scroll Factor 5 0 - 255 255
15 Filter 2nd Cartridge Scroll Factor 6 0 - 255 255
16 Filter 2nd Cartridge Scroll Factor 7 0 - 255 255
17 Filter 2nd Cartridge Scroll Factor 8 0 - 255 255
18 Filter 2nd Cartridge Scroll Factor 9 0 - 255 255
19
Filter 2nd Cartridge Scroll Factor 10
0 - 255 255
20 Filter 3rd Cartridge Scroll Factor 1
3rd Filter Cartridge Scrolling Factor at N times Scrolling (N:1-10)
0: Manual Scrolling with OSD Menu
1: Auto Scrolling detecting by Filter Clogged
2: Auto Scrolling detecting by specified maximum used time per
a sheet
0 - 255 255
21 Filter 3rd Cartridge Scroll Factor 2 0 - 255 255
22 Filter 3rd Cartridge Scroll Factor 3 0 - 255 255
23 Filter 3rd Cartridge Scroll Factor 4 0 - 255 255
24 Filter 3rd Cartridge Scroll Factor 5 0 - 255 255
25 Filter 3rd Cartridge Scroll Factor 6 0 - 255 255
26 Filter 3rd Cartridge Scroll Factor 7 0 - 255 255
27 Filter 3rd Cartridge Scroll Factor 8 0 - 255 255
28 Filter 3rd Cartridge Scroll Factor 9 0 - 255 255
29
Filter 3rd Cartridge Scroll Factor 10
0 - 255 255
250 Fan Voltage Adjustment
0 Fan 1 Min Adjust (DAC)
DAC Output for Fan Voltage adj.
Adjust Tolerance between DAC and Fan Volt.
*Lamp Mode: Eco
0-255 32 * Fan voltage adj.
1 Fan 1 Max Adjust (DAC) 0-255 240 * Fan voltage adj.
2 Fan 2 Min Adjust (DAC) 0-255 32 * Fan voltage adj.
3 Fan 2 Max Adjust (DAC) 0-255 240 * Fan voltage adj.
4 Fan 3 Min Adjust (DAC) 0-255 32 * Fan voltage adj.
5 Fan 3 Max Adjust (DAC) 0-255 240 * Fan voltage adj.
6 Fan 4 Min Adjust (DAC) 0-255 35 * Fan voltage adj.
7 Fan 4 Max Adjust (DAC) 0-255 230 * Fan voltage adj.
8 Fan 5 Min Adjust (DAC) 0-255 35 * Fan voltage adj.
9 Fan 5 Max Adjust (DAC) 0-255 230 * Fan voltage adj.
10 Fan 6 Adjust (DAC) 0-255 190 * Fan voltage adj.
11 Fan 7 Adjust (DAC) 0-255 190 * Fan voltage adj.
12 Fan 8 Adjust (DAC) 0-255 190 * Fan voltage adj.
252 Fan Option
1 Safety Switch Safety Application use 0-6 0
2 Fan Manual Switch Fan Manual SW (0: Auto 1: Manual) 0-1 0
3 Fan1 Manual Voltage
Manual Adjustment Mode (0.1V)
*Effective only when Manual SW is 1.
0-255 100
4 Fan2 Manual Voltage 0-255 100
5 Fan3 Manual Voltage 0-255 100
6 Fan4 Manual Voltage 0-255 100
7 Fan5 Manual Voltage 0-255 100
8 Fan6-8 Manual Voltage 0-255 100
9 All Fan Max Min Control
Forced mode of Lamp mode - Fan Control.
0: Normal, 1: High-MIN, 2: High-MAX, 3: Normal-MIN, 4:
Normal-MAX, 5: Eco1-MIN, 6: Eco1-MAX, 7: Eco2-MIN, 8: Eco2-
MAX
0 - 8 0
10 Press Data Air Pressure Data (Read only) - -
253 Fan Temp Error Setting (Memorized) Normal Ceiling Top Bottom
0 Temp A Warning (High) Temp A (Room) to judge the Temp Error at High 30-100 51 51 51 51
1 Temp B Warning (High) Temp B (Lamp) to judge the Temp Error at High 30-100 64 64 64 64
2 Temp C Warning (High) Temp C (Panel) to judge the Temp Error at High 30-100 59 59 59 59
3 Temp B-A Warning (High) Temp B - A (Filter Clogged) to judge the Temp Error at High 0-100 100 100 100 100
4 Temp C-A Warning (High) Temp C - A (Filter Clogged) to judge the Temp Error at High 0-100 100 100 100 100
5 Temp A Warning (Normal) Temp A (Room) to judge the Temp Error at Normal 30-100 51 51 51 51
6 Temp B Warning (Normal) Temp B (Lamp) to judge the Temp Error at Normal 30-100 64 64 64 64
7 Temp C Warning (Normal) Temp C (Panel) to judge the Temp Error at Normal 30-100 59 59 59 59
8 Temp B-A Warning (Normal) Temp B - A (Filter Clogged) to judge the Temp Error at Normal 0-100 100 100 100 100
9 Temp C-A Warning (Normal) Temp C - A (Filter Clogged) to judge the Temp Error at Normal 0-100 100 100 100 100
10 Temp A Warning (Eco) Temp A (Room) to judge the Temp Error at Eco 30-100 51 51 51 51