-11-
Maintenance
How to check Lamp Used Time
The LAMP REPLACE indicator will light yellow when
the total lamp used time (Corresponding value) reaches
3,000 hours. This is to indicate that lamp replacement
is required.
The total lamp used time is calculated by using the be-
low expression,
Total lamp used time = Teco + Tnormal x 2
Teco: used time in the Eco mode
Tnormal : used time in the Normal mode and Auto
mode.
You can check the lamp used time following to the below
procedure.
1 Press and hold the ON/STAND-BY button on the pro-
jector for more than 20 seconds.
2 The projector used time and lamp used time will be
displayed on the screen briefly as follows.
Counter
Projector 525H
Lamp
Normal 150H
Eco 375H
Corresponding value 675H
Total lamp used time
Projector used time
Cleaning
Cleaning with air spray
1. Remove the cabinet top following to “Mechanical Dis-
assemblies”.
2. Clean up the LCD panel and polarizing plate by using
the air spray from the cabinet top opening.
Caution:
Use a commercial (inert gas) air spray designed for
cleaning camera and computer equipment. Use a resin-
based nozzle only. Be very careful not to damage optical
parts with the nozzle tip. Never use any kind of cleanser
on the unit. Also, never use abrasive materials on the
unit as this may cause irreparable damage.
After long periods of use, dust and other particles will accumulate on the LCD panel, prism, mirror, polarized glass,
lens, etc., causing the picture to darken or color to blur. If this occurs, clean the inside of optical unit.
Remove dust and other particles using air spray. If dirt cannot be removed by air spray, disassemble and clean the
optical unit.
Disassembly Cleaning
Disassembly cleaning method should only be performed
when the unit is considerable dirty and cannot be suf-
ficiently cleaned by air spraying alone.
Be sure to readjust the optical system after perform-
ing disassembly cleaning.
1. Remove the cabinet top and main units following to
“Mechanical Disassemblies”.
2. Remove the optical base top following to “Optical Unit
Disassemblies”. If the LCD panel needs cleaning, re-
move the LCD panel unit following to “LCD panel re-
placement”.
3. Clean the optical parts with a soft cloth. Clean ex-
tremely dirty areas using a cloth moistened with al-
cohol.
Caution:
The surface of the optical components consists of mul-
tiple dielectric layers with varying degrees of refraction.
Never use organic solvents (thinner, etc.) or any kind of
cleanser on these components.
Since the LCD panel is equipped with an electronic cir-
cuit, never use any liquids (water, etc.) to clean the unit.
Use of liquid may cause the unit to malfunction.