-32-
Electrical Adjustments
1. Enter the service mode.
2. Receive the 16-step grey scale computer signal with
Computer2 [RGB] mode.
3. Connect an oscilloscope to test point TP_G1 (+)
and chassis ground (-).
4. In standard mode, select group no. 100”, item no.
6and change data value to adjust amplitude ato
be 1.6V.
(a)
white level
white level
7. 50% White adjustment [PC]
1. Enter the service mode,
2. Receive the 16-step gray scale computer signal with
Computer2 [RGB] mode.
3. Select group no. 100item no. 7(Red) or 8(Blue),
and change Data values respectively to make a prop-
er white balance.
Confirm that the same white balance is obtained in video
and computer input.
8. White Balance adjustment [PC]
1. Enter the service mode.
2. Receive the 16-step grey scale composite video sig-
nal with Video mode.
3. Connect an oscilloscope to test point TP_G1 (+)
and chassis ground (-).
4. In standard mode, select group no. 100”, item no.
6and change data value to adjust amplitude ato
be 1.6V.
(a)
white level
white level
9. 50% White adjustment [Video]
1. Enter the service mode.
2. Receive the 16-step grey scale composite video sig-
nal with Video mode.
3. Select group no. 100item no. 7(Red) or 8(Blue),
and change Data values respectively to make a prop-
er white balance.
Confirm that the same white balance is obtained in video
and computer input.
10. White Balance adjustment [Video]