-44-
Electrical Adjustments
Group/
Item
Item Name Function Initial Range Note
0
Logo Prohibition (Forced No
Brand)
Logo Prohibition (0: Menu, 1: Forced, 2:
China, 3-9: not used)
0 0 - 2
Effective after AC
On
1 RS232C Baudrate Baud Rate 0 0 - 2
0: 19200bps,
1: 9600bps, 2:
115200bps
2 PJLink 0:Disable 1:Enable 1
3 Shipping Setting 0 0 - 20
Default set when
the value is set to
10
4 CABLE SW Long Cable 0 0 - 1
0: Disable,
1: Enable
5
PW Debug Command
Enable
0 0 - 1
0:Disable (Serial
Command Eanble)
1: Enable (PW
Debug Mode)
6 Device Refresh Disable 0 0 - 1
0:Enable, 1:Disable
No last memory
7 Device Access Disable 0 0 - 1
0:Enable (Normal),
1:Disable
No last memory
20 Projector Time Reset 0 0 - 20
Projector Time is
cleared when the
value is set to 10
21
Lamp Warning Time
(NORMAL)
Lamp Life at Normal Mode (Warning Time at
Normal)
500 -
8000
22 Lamp Warning Time (ECO) Lamp Life at Eco Mode (Warning Time at Eco)
500 -
8000
23 Lamp Warning Time (HIGH)
Lamp Life at High Mode (Warning Time at
High)
500 -
8000
30 Lamp life test enable 0
0:Disable 1:Enable,
for safety test only
31 Lmap On time(for life test) For test purpose 1
32 Lamp Off time(for life test) For test purpose 3
33 Lamp total time(for life test) For test purpose 0
40 Lamp PWM PresAv 50Hz Lamp PWM PRES0 setting (AV50Hz) 80 0-255
41 Lamp PWM PresAv 60Hz Lamp PWM PRES0 setting (AV60Hz) 67 0-255
42 Lamp PWM PresUnlock Lamp PWM REFS0 setting (no signal) 67 0-255
43 Lamp PWM PresPcA
Lamp PWM frequency setting coeddicient A
(PC)
2 0-255
44 Lamp PWM PresPcB
Lamp PWM frequency setting coeddicient B
(PC)
3 0-255
45 Lamp PWM PrefHAv50Hz Lamp PWM PREF0 settng (AV50Hz) 5000 0-65535
46 Lamp PWM PreHAv60Hz Lamp PWM PREF0 setting (AV60Hz) 5000 0-65535
47 Lamp PWM PrefHUnlock Lamp PWM PREF0 setting (no siginal) 5000 0-65535
50 Lamp Replacement Display Lamp Warning Display On / Off 1 0 - 1 1: On, 0: Off
51 Filter Warning Display Filter Warning Display On / Off 1 0 - 1 1: On, 0: Off
52 Lamp Counter reset Times Reset Times of Lamp Counter 0 0 - 255 Read only
53 Filter Counter Reset Times Reset Times of Filter Counter 0 0-255
54
Factory Default Execute
Times
Reset times of Fanctory Default 0 0 - 255 Read only
55 Motor Disable Motors Disable 0 0 - 1 0: On, 1: Off
56 Menu Position Move menu (X axis) 0 0 - 1024
57 Menu Position Move menu (Y axis) 0 0 - 1024
58 Lamp Go Out 0 0 - 1
59 Souce Search Enable Source Search Enable 0 0 - 1
(0:Disable 1:Enable)
60 Language Default setting Set dafault language 0: English (Default) / 1: Japanese - 0-1
80
Panel life test mode Set panel life test mode 1 0-1 0: Life test mode /
1: Normal
Group 201 Option (signal)
0 FrameLock Option 1 0 - 1
0: FrameLockOFF
at PC signal
1: FrameLockON at
PC signal and 47Hz
(Vfreq) ~ Panel
frequency of input
signal
1 AV TRUE Change to AV Signal True 0 0-1
0: effective 1:
invalid (it is TRUE
when "Natural
Wide" is selected.
2 Field Sense Invert Enable 0 0 - 1
Reverse
Processing of
FLDINVSetting
Value
0: Disable - Used
FLDINV Setting
Value
1: Enable - Used
Reversed FLDINV
Setting Value