-14-
This projector provides a cabinet front cover on the cabinet top to enhance the service maintenance. This enables
service personnel to align the optical adjustment or replace the optical parts without disassembly the cabinet top.
1. Press and hold the release button the cabinet front cover and slide the cover frontward to take it off.
2. Remove 2 screws A on the prism shield cover and take prism shield cover off.
3. Loosen 4 screws B and take the LCD Panel/Prism ass'y upward off.
4. Remove 1 screw C on each stopper of the optical filter ass'y and take the optical filter ass'y upward off.
See chapter "Optical Parts Disassembly" for further information of optical parts disassembly.