-77-
Chassis Description
Error Error Code
Error Infomation
(See Powe Failure Detection Tree)
Normal 0 -
Power Failure
1000 PJNET, S5V
1001 AV, S-5V
1002 AV, S5V
1003 MAIN, S-5V
1004 M/A, 9V
1005 FAN, 16V
1006 SWFPGA1, 1.2V
1007 SWFPGA1, 2.5V
1008 VDEC, 1.8V
1009 FPGA2, 1.5V
1010 MAIN, 6V
1011 MAIN, 3.3V
1012 ANALOG, 3.3V
1013 VDEC, 3.3V
1014 GAMMA, 1.8V
1015 GAMMA, 2.5V
1016 GAMMA, 3.3V
1017 GAMMA, 13.5V
1018 LAMP FAN, 16V
1019 LENS, 9V
1020 LENS, 15V
1021 SWFPGA, CONFIG
1022 FPGA, CONFIG
1023 PW, DPORT OUT
1024 FILTER DET
1025 MOTOR, TIMEOUT
1026 PRESS, ERROR
Temperature Error
2000
Sensor A detects abnormal temperature. (IC1816)
2001
Sensor A fails measurement. (IC1806)
2100
Sensor B detects abnormal temperature. (IC1814)
2101
Sensor B fails measurement. (IC1814)
2102
Sensors B-A temperature error.
2200 Sensor C detects abnormal temperature. (IC1692)
2201 Sensor C fails measurement. (IC1692)
2202
Sensors C-A temperature error.
Lamp Error
3000 Lamp1 fails on
3001 Lamp1 goes out
3002
Communication Error on Lamp1
Filter Error
4000 Air Filter is not installed
4001 Wind Sensor Error
4002
Filter Scroll Motor Error
Error History Log
This projector provides the error history log function. To
check the logs, you need to enter the service mode and se-
lect Group No. "91" and Item No. "0" to "49". The error code
is displayed on the Data column. The description of the error
code is listed on the table below.
* How to enter the service mode and select the group, item
and data value, see "Service Adjustment Menu Opera-
tion".
Group
No.
Item
No.
Data
(Error Code)
91 0
1
2
3
:
:
49
✻
<- Latest Error
:
:
How to reset the Error History Log
1. Enter the Service Mode, and select Group No. "91" and Item No. "50".
2 The history log will be reset when the Data Value is set to "10". The value automatically returns to "0".
* How to enter the service mode and select the group, item and data value, see "Service Adjustment Menu Operation".