EasyManua.ls Logo

Sanyo PLC-XP100L - Optical Unit Removal; Lens Shift Motor Assy Removal

Sanyo PLC-XP100L
156 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
-23-
Mechanical Disassembly
7 Optical unit removal
1 Remove 7 screws A (T4x12) and 2 screws B (T3x8),
disconnect ballast socket and take the optical unit up-
ward off.
7-1 Lens shift motor ass’y removal
1 Remove 2 screws B (M3x6) and take the lens shift mo-
tor ass’y off.
2 Remove 1 screw C (T3x6) and take the lens shift sen-
sor board off.
3 Remove 2 screws D (T2x4) and take the lens shift mo-
tor off
A
Lens shift motor
A
A
B
B
A
B
B
A
C
C
D
D
Lens shift motor
Sensor board
Sensor board
B
B
A