-82-
Control Port Functions
Pin No. Function Name Function Pol.
Action
Stand-by Power On
31 ZOOM+_EX Zoom Up O
L: Active H: Not Active
32 ZOOM-_EX Zoom Down O
L: Active H: Not Active
33 LENS_DOWN_EX Lens Shift Down O
L: Active H: Not Active
34 LENS_UP_EX Lens Shift Up O
L: Active H: Not Active
35 LENS_BOT Lens Bottom Detection I
L: Lens Bottom
36 LENS_TOP Lens Top Detection I
L: Lens Top
37 POWER_LED Power LED On/Off O
L: Bright H: Dark
38 READY_LED_EX Ready LED On/Off O
L: On H: Off
39 TEMP_LED_EX Temp LED On/Off O
L: On H: Off
40 LAMP_REP_LED_EX Lamp Replece LED On/Off O
L: On H: Off
41 PJ_UPDATE PJ-Net Write Forced O
L: Write Mode H: Normal
42 PLLSTB_EX CXD3531 Reset O L Fixed PLLSTB,RST_GAM = H,L L,L L,H Reset
43 SH_PW_0 (SH_RESET_EN) Software Protect O
L: Reset Enable H: Reset Disable
44 W-SW Wired RC Detect I
H: Not Inserted L: Inserted
45 SH_CHK_DPRAM PW INT Clear Monitor Input I
L: INT Not Cleared
46 15V_LNS_PF 15V_LNS Power Fail Detect I
47 9V_LNS_PF 9V_LNS Power Fail Detect I
48 C_READY I
Not used
49 O
50 GND - - - -
51 S3.3V - - - -
52 RC_CTL_0 Rear RC Receiver Switch O
L: Rear Select
53 RC_CTL_1 FrontRC Receiver Switch O
L: Front Select
54 FPGA_HZ FPGA Hi-Z (DRAM Reaet) O
H after configuration
55 SH_BSY DPRAM Access Control Output O
L: BUSY
56 LAMP_FAN_PF LAMP_FAN Power Fail Detect I
L: Error
57 LENS_LEFT_EX Lens Shift Left O
L: Active H: Not Active
58 LENS_RIGHT_EX Lens Shift Right O
L: Active H: Not Active
59 LENS_L_POS Lens Left Position Detect I
L: Limited Position
60 LENS_R_POS Lens Right Position Detect I
L: Limited Position
61 FILTER_LED_EX Filter LED On/Off O
L: On H: Off
62 GAM_1.8V_PF GAM_1.8V Power Fail Detect I L: Error
63 GAM_2.5V_PF GAM_2.5V Power Fail Detect I
64 PJ_5V_PF PJ_5V Power Fail Detect I
L: Error
65 -5V_AV_PF -5V_AV Power Fail Detect I
L: Error
66 S5V_AV_PF S5V Power Fail Detect I
L: Error
67 MAIN_5V_PF MAIN_5V Power Fail Detect I
L: Error
68 M/A_PF M/A Power Fail Detect I Not Checked L: Error
69 FAN_PF FAN Power Fail Detect I
L: Error
70 SWF_1.2V_PF SWF_1.2V Power Fail Detect I
L: Error
71 SWF_2.5.V_PF SWF_2.5.V Power Fail Detect I
L: Error
72 VDEC_1.8V_PF VDEC_1.8V Power Fail Detect I Not Checked L: Error
73 FPGA_1.5V_PF FPGA_1.5V Power Fail Detect I Not Checked L: Error
74 GAM_15.5V_PF GAM_15.5V Power Fail Detect I Not Checked L: Error
75 S3.3V - - - -
76 GND - - - -
77 MAIN_6V_PF MAIN_6V Power Fail Detect I Not Checked L: Error
78 MAIN_3.3V_PF MAIN_3.3V Power Fail Detect I Not Checked L: Error
79 GND - - - -
80 AD_3.3V_PF AD_3.3V Power Fail Detect I Not Checked L: Error
81 GND - - - -
82 VEC_3.3V_PF I
83 Not used Not used I
84 MOUSE_TXD PJ-Net Mouse Data Output O
85 GND - - - -
86 GAM_3.3V_PF I
87 S3.3V - - - -
88 13.5V_PF I
89 PJ_SH_UART1 PJ-Net Command (SH:RXD) I
Normal:19200bps PJ-Net:76800bps
90 SH_PJ_UART1 PJ-Net Command (SH:TXD) O
Normal:19200bps PJ-Net:76800bps
91 GND - - - -
92 Not used Not used I
L Fixed
93 GND - - - -
94 Not used Not used O
L Fixed
95 IRQ0 PJ-Net Serial Interrupt Output O
Active H
96 ??? Air Mouse Serial Interrupt Output O
97 PRODUCT_OPT1 Product Option I
H: Product
98 PRODUCT_OPT2 Product Option I
H: Product
99 GND - - - -
100 GND - - - -