48 NOR_VALU_FAN2_MIN M62398FP 81 0-255 FAN2 Control Min at Normal
49 NOR_VALU_FAN2_MAX M62398FP 132 FAN2 Control Max at Normal
50 ECO_TEMP_FAN1_MIN PW186 47 FAN1 Control start temp.at Eco
51 ECO_TEMP_FAN1_MAX PW186 50 FAN1 Control end temp. at Eco
52 ECOTEMP_FAN2_MIN PW186 47 0-255 FAN2 Control start temp.at Eco
53 ECO_TEMP_FAN2_MAX PW186 50 FAN2 Control end temp. at Eco
54 ECO_VALU_FAN1_MIN PW186 52 FAN1 Control Min at Eco
55 ECO_VALU_FAN1_MAX PW186 115 FAN1 Control Max at Eco
56 ECO_VALU_FAN2_MIN PW186 65 0-255 FAN2 Control Min at Eco
57 ECO_VALU_FAN2_MAX PW186 89 FAN2 Control Max at Eco
58 HINOR_TEMP_FAN1_MIN PW186 48 FAN1 Control start temp.at Highland Normal
59 HINOR_TEMP_FAN1_MAX PW186 48 FAN1 Control end temp. at Highland Normal
60 HINOR_TEMP_FAN2_MIN PW186 48 0-255 FAN2 Control start temp.at Highland Normal
61 HINOR_TEMP_FAN2_MAX PW186 48 FAN2 Control end temp. at Highland Normal
62 HINOR_VALU_FAN1_MIN M62398FP 135 FAN1 Control Min at Highland Nromal (0:0V, 255:25.5V)
63 HINOR_VALU_FAN1_MAX M62398FP 135 FAN1 Control Max at Highland Normal
64 HINOR_VALU_FAN2_MIN M62398FP 135 0-255 FAN2 Control Min at Highland Normal
65 HINOR_VALU_FAN2_MAX M62398FP 135 FAN2 Control Max at Highland Normal
66 HIECO_TEMP_FAN1_MIN PW186 48 FAN1 Control start temp.at Highland Eco
67 HIECO_TEMP_FAN1_MAX PW186 48 FAN1 Control end temp. at Highland Eco
68 HIECOTEMP_FAN2_MIN PW186 48 0-255 FAN2 Control start temp.at Highland Eco
69 HIECO_TEMP_FAN2_MAX PW186 48 FAN2 Control end temp. at Highland Eco
70 HIECO_VALU_FAN1_MIN M62398FP 120 FAN1 Control Min at Highland Eco
71 HIECO_VALU_FAN1_MAX M62398FP 120 FAN1 Control Max at Highland Eco
72 HIECO_VALU_FAN2_MIN M62398FP 91 0-255 FAN2 Control Min at Highland Eco
73 HIECO_VALU_FAN2_MAX M62398FP 91 FAN2 Control Max at Highland Eco
74 CLNOR_TEMP_FAN1_MIN PW186 47 FAN1 Control start temp.at Ceiling Normal
75 ClNOR_TEMP_FAN1_MAX PW186 50 FAN1 Control end temp. at Ceiling Normal
76 CLNOR_TEMP_FAN2_MIN PW186 41 0-255 FAN2 Control start temp.at Ceiling Normal
77 CLNOR_TEMP_FAN2_MAX PW186 53 FAN2 Control end temp. at Ceiling Normal
78 CLNOR_VALU_FAN1_MIN M62398FP 68 FAN1 Control Min at Ceiling Nromal (0:0V, 255:25.5V)
79 CLNOR_VALU_FAN1_MAX M62398FP 135 FAN1 Control Max at Ceiling Normal
80 CLNOR_VALU_FAN2_MIN M62398FP 80 0-255 FAN2 Control Min at Ceiling Normal
81 CLNOR_VALU_FAN2_MAX M62398FP 132 FAN2 Control Max at Ceiling Normal
82 CLECO_TEMP_FAN1_MIN PW186 47 FAN1 Control start temp.at Ceiling Eco
83 CLECO_TEMP_FAN1_MAX PW186 50 FAN1 Control end temp. at Ceiling Eco
84 CLECOTEMP_FAN2_MIN PW186 47 0-255 FAN2 Control start temp.at Ceiling Eco
85 CLECO_TEMP_FAN2_MAX PW186 50 FAN2 Control end temp. at Ceiling Eco
86 CLECO_VALU_FAN1_MIN M62398FP 52 FAN1 Control Min at Ceiling Eco
87 CLECO_VALU_FAN1_MAX M62398FP 115 FAN1 Control Max at Ceiling Eco
88 CLECO_VALU_FAN2_MIN M62398FP 65 0~255 FAN2 Control Min at Ceiling Eco
89 CLECO_VALU_FAN2_MAX M62398FP 89 FAN2 Control Max at Ceiling Eco
90 FAN_1_AUTO_ADJ PW186 0 0-1 0: OFF(Manual) 1:ON(Auto)
91 FAN_2_AUTO_ADJ PW186 0 0-1 0: OFF(Manual) 1:ON(Auto)
92 FACTORY_STD_FAN_VOL_MIN PW186 52 0-255 For Factory
93 FACTORY_STD_FAN_VOL_MAX PW186 135 0-255 For Factory
94 FAN1_ADJUST_VOLT_MIN M62398FP 15 For Factory
95 FAN1_ADJUST_VOLT_MAX M62398FP 203 For Factory
96 FAN2_ADJUST_VOLT_MIN M62398FP 15 0~255 For Factory
97 FAN2_ADJUST_VOLT_MAX M62398FP 203 For Factory
98
TEMP_ERROR_DETECT_MAX_
TIMES
5 1-9 Detecting times for Temp Error
99 FAN_1_MIN_VOL_LAMP_DIFF 0 0-20
100 FAN_2_MIN_VOL_LAMP_DIFF 0 0-20
101 LAMP_VOL_BORDER_LINE 70 30-90
102 LAMP_VOL - 0-255 Present Lamp Voltage
103 Dimmer Voltage Change Cycle 3 Change cycle of voltage at Dimmer
104 Dimmer Avarage Check Period 10 Measurement time of Dimmer average
105 Dimmer Voltage Change Rate 1 Voltage change rate ta Dimmer
106 Dimmer Average - Dimmer average
107 Last Voltage Difference - Last voltage difference
108 Voltage Difference Goal - Target voltage difference at Dimmer
109 Fan Control TempDiff Normal PW186 0 0-10 Fan control temp. augment temp. Normal
110 Fan Control TempDiff Eco PW186 0 0-10 Fan control temp. augment temp. Eco
111
Fan Contro TempDiff HighLand Normal
PW186 0 0-10 Fan control temp. augment temp. HighLand Normal
112 Fan Control TempDiff HiLand Eco PW186 0 0-10 Fan control temp. augment temp. HighLand Eco
113 Fan Control TempDiff Ceiling Normal PW186 0 0-10 Fan control temp. augment temp. Ceiling Normal
114 Fan Control TempDiff Ceiling Eco PW186 0 0-10 Fan control temp. augment temp. Ceiling Eco
115 Fan Control Temp UpTime Normal PW186 0 0-5 Fan control temp. augment time Normal
116 Fan Control Temp UpTime Eco PW186 0 0-5 Fan control temp. augment time Eco
117
Fan Contol Temp UpTime HighLand Normal
PW186 0 0-5 Fan control temp. augment time HighLand Normal
118
Fan Control Temp UpTime highLand Eco
PW186 0 0-5 Fan control temp. augment time HighLand Eco
119
Fan Contol Temp UpTime Celing Normal
PW186 0 0-5 Fan control temp. augment time Ceiling Normal
120
Fan Contol Temp UpTime Celing Eco
PW186 0 0-5 Fan control temp. augment time Ceiling Eco
121
Standby Cooling Temp Check Cycle
PW186 5 1-30 Room temp sensor check cycle at standby cooling for MCI
122
Standby Cooling Start Threshold Temp
PW186 54 0-100 Standby cooling starting temp for MCI
123
Standby Cooling Disable/Enable
PW186 1 0-1 Standby cooling On/Off for MCI 0: OFF, 1: ON
Group 200 Auto Calibration
0 Execute Calibration PW186 0 0 - 255 Auto executiong when value changes
1 Loop Count PW186 3 1 - 30 Loop times of Auto Calibration