Lamp Replacement
The LAMP REPLACE indicator will light when the total
lamp used time reaches 3,000 hours. This is to indicate
that lamp replacement is required.
The total lamp used time is calculated by using the below
expression;
Total lamp used time = Teco + Tnormal x (1.5)
Teco: used time in Eco mode
Tnormal: used time in Normal/Auto1/Auto2 mode
You can check the lamp counter following procedure.
1 Press and hold the POWER ON/STAND-BY button on
the projector or the remote control unit for more than
20 seconds.
2 The projector used time and lamp used time will be dis-
played on the screen briefly.
You can also check "Lamp Time" in the "Information
Menu". This value is actual lamp used time.
"Lamp Time" = Teco + Tnormal
How to check lamp used time
Counter
Projector 475H
Lamp
Normal 100H
Eco 375H
Corresponding value
525H
Total lamp used time
Information Menu
Lamp Counter Display
Projector used time
Total lamp used time (actual)
475

Other manuals for Sanyo PLV-Z2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sanyo PLV-Z2000 and is the answer not in the manual?

Sanyo PLV-Z2000 Specifications

General IconGeneral
Vertical scan range50 - 100 Hz
Horizontal scan range15 - 80 kHz
Projection technologyLCD
Contrast ratio (typical)-
FocusManual
Digital zoom2 x
Focal length range22.6 - 45.3 mm
RS-232 ports1
Dimensions (WxDxH)400 x 346 x 146 mm
Power requirements100 - 240V
Connectivity technologyWired
Lamp typeUHP
Lamp power165 W
Light source typeLamp
Full HDYes
Serial interface typeRS-232
Component video (YPbPr/YCbCr) in2
Noise level26 dB
Power consumption (typical)240 W
Weight and Dimensions IconWeight and Dimensions
Weight7300 g

Related product manuals