This projector uses a high-pressure lamp which must be handled carefully and properly. Improper handling may result in
accidents, injury, or create a fire hazard.
Lamp lifetime may differ from lamp to lamp and according to the environment of use. There is no guarantee of the same
lifetime for each lamp. Some lamps may fail or terminate their lifetime in a shorter period of time than other similar lamps.
If the projector indicates that the lamp should be replaced, i.e., if the LAMP REPLACE indicator lights up, replace the lamp
with a new one IMMEDIATELY after the projector has cooled down.
(Follow carefully the instructions in the Lamp Replacement section of this manual.) Continuous use of the lamp with the
LAMP REPLACE indicator lighted may increase the risk of lamp explosion.
A Lamp may explode as a result of vibration, shock or degradation as a result of hours of use as its lifetime draws to an end.
Risk of explosion may differ according to the environment or conditions in which the projector and lamp are being used.
IF A LAMP EXPLODES, THE FOLLOWING SAFETY PRECAUTIONS SHOULD BE TAKEN.
If a lamp explodes, disconnect the projectors AC plug from the AC outlet immediately. Contact an authorized service station
for a checkup of the unit and replacement of the lamp. Additionally, check carefully to ensure that there are no broken shards
or pieces of glass around the projector or coming out from the cooling air circulation holes. Any broken shards found should
be cleaned up carefully. No one should check the inside of the projector except those who are authorized trained technicians
and who are familiar with projector service. Inappropriate attempts to service the unit by anyone, especially those who are
not appropriately trained to do so, may result in an accident or injury caused by pieces of broken glass.
LAMP HANDLING PRECAUTIONS
Be sure to reset the lamp replacement counter after the lamp is replaced. When the lamp replacement counter is reset, the LAMP
REPLACE indicator stops lighting.
Lamp Replacement Counter
Turn the projector on and press the MENU button to display the
On-Screen Menu. Select the Setting Menu with the Point ed
buttons. Press the Point 8 or OK buttons to access the submenu
items.
Select Lamp counter reset and then press the OK or Point 8
buttons. “Lamp replacement counter reset?” appears. Select [Yes]
and then press the OK button.
1
2
Another confirmation dialog box appears, and select [Yes] to
reset the Lamp replacement counter.
3
Note:
Do not reset the Lamp replacement counter without implementing lamp
replacement. Be sure to reset the Lamp replacement counter only after
replacing the lamp.
Lamp counter reset
Select Lamp counter reset
and press the OK or Point 8
buttons. “Lamp replacement
counter reset?” appears.
Select [Yes] and press
the OK button, then
another confirmation
box appears.
Select [Yes] again to reset
the lamp counter.
Lamp Replacement

Other manuals for Sanyo PLV-Z2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sanyo PLV-Z2000 and is the answer not in the manual?

Sanyo PLV-Z2000 Specifications

General IconGeneral
Vertical scan range50 - 100 Hz
Horizontal scan range15 - 80 kHz
Projection technologyLCD
Contrast ratio (typical)-
FocusManual
Digital zoom2 x
Focal length range22.6 - 45.3 mm
RS-232 ports1
Dimensions (WxDxH)400 x 346 x 146 mm
Power requirements100 - 240V
Connectivity technologyWired
Lamp typeUHP
Lamp power165 W
Light source typeLamp
Full HDYes
Serial interface typeRS-232
Component video (YPbPr/YCbCr) in2
Noise level26 dB
Power consumption (typical)240 W
Weight and Dimensions IconWeight and Dimensions
Weight7300 g