User Manual CA-5
8
zone violation is displayed - it may be caused e.g. by the detector failure), the armed mode
can be activated after bypassing the given zone (using the function 4);
the access code is incorrect – this situation is signaled with two long beeps.
at least one output in the system performs the D
URESS ALARM
function and is on (active).
Using the code which does not carry out the „action under duress” function will reset the
a.m. output activity (three short beeps) without arming the system; the system will only be
armed on using any code again.
4.8 Q
UICK ARMING
[0][#]
Quick arming without using any access code is possible by consecutive pressing of two
keypad keys:
EXAMPLE: [0][#] - arming
The control panel cannot arm the system when:
an alarm condition is signaled by the panel (the ALARM LED is blinking);
the panel is not ready to arm the system - which is signaled by the panel with three long
beeps (see description in the previous paragraph of this manual);
the function is disabled by the installer – this situation will be signaled with two long beeps.
4.9 D
ISARMING AND ALARM CLEARING
[CODE][#]
If the panel is armed (the ARMED LED is on or blinking) and/or it signals an alarm (the
ALARM LED is on or blinking), entering the user access code and confirming it with the [#] or
[
*
] key will disarm the system and clear the alarm. If, while entering the access code, you
make a mistake, press the [
*
] key and re-enter the code. The control panel will confirm
acceptance of the command by four short beeps and a long one, and by extinguishing the
ARMED LED and/or ALARM LED (if it was on).
The service code can only clear the tamper alarm or the keyboard alarm when the ARMED
LED is off (the control panel is disarmed).
The panel will not disarm the system or clear the alarm when the access code is wrong.
The user access code No. 5 will not clear the alarm in the armed mode if it has been
assigned a special authority level, and the system was armed by another user.
Refusal to clear the alarm is signaled with three long beeps.
4.10 R
EMOTE ARMING
/
DISARMING AND CLEARING ALARM
The installer may install in the security system a special remotely controlled radio line, or
a special button, designed for quick arming/disarming of the system or clearing of alarm. For
this purpose, one of the control panel programmable zones is used. The system will be
always armed in this mode (by violation of the zone), irrespective of the status (violation) of
the other zones of the control panel.
The zone can work in two modes:
bistable - the control panel is armed when the zone is violated, and it is disarmed when the
zone is in its normal mode (not violated),
monostable – each violation of the zone will change the control panel state to the opposite
one (i.e. it will arm the system when the panel was disarmed, and it will disarm the system
and clear the alarm if the panel was armed (and alarming). In the monostable mode, the
installer may restrict the zone operation to arming only, while disarming and alarm clearing
will require the user access code.
To facilitate remote control of the panel, the installer may activate the signaling of
arming/disarming on the OUT1 alarm output (see: Events Signaled on the OUT1 Output).